This study will explore new ways of using magnetic resonance imaging (MRI) to evaluate the heart and blood vessels of patients with cardiovascular disease, including better detection of myocardial infarction (heart attack) and blockage of heart and leg arteries. Patients 21 years of age and older with cardiovascular disease may be eligible for this study. All participants will have magnetic...
Date First Received: November 27, 2001
Last Updated: July 18, 2008
Verified by: National Institutes of Health Clinical Center (CC), October 2007
Clinical Trial Phase: Phase 4 | Start Date: November 2001
Overall Status: Suspended
Estimated Enrollment: 839
Brief Summary
Official Title: “Technical Development of Cardiovascular Magnetic Resonance Imaging”
Condition Keyword(s):
Intervention(s):
This study will explore new ways of using magnetic resonance imaging (MRI) to evaluate the heart and blood vessels of patients with cardiovascular disease, including better detection of myocardial infarction (heart attack) and blockage of heart and leg arteries.
Patients 21 years of age and older with cardiovascular disease may be eligible for this study.
All participants will have magnetic resonance imaging of the heart. MRI uses a magnetic field and radio waves to show structural and chemical changes in tissues. For the procedure, the patient lies on a table surrounded by a metal cylinder (the scanner). A 'gadolinium contrast' material may be injected into the patient's vein during part of the study to brighten the images. Patients wear earplugs during the scan to muffle loud knocking sounds caused by the electrical switching of the magnetic fields. They will be asked to hold their breath intermittently for 5 to 20 seconds during the scan. They will be monitored with an electrocardiogram (EKG) during the procedure and will be in contact by intercom at all times with the person performing the scan. Patients can request to stop the study and come out of the scanner at any time. The procedure may last from 30 to 90 minutes. An echocardiogram-a test that uses sound waves to produce pictures of the heart and blood vessels-may be done to confirm the MRI findings. In addition, patients may undergo one or more of the following optional studies: - Dobutamine stress MRI - This test uses dobutamine-a medicine that simulates exercise by increasing heart rate and heart function-to detect blockages in the coronary arteries (vessels that supply oxygen and nutrients to the heart) and locate areas of the heart that are permanently damaged, perhaps by a previous heart attack. For this test, MRI pictures of the heart are taken before, during and after administration of dobutamine.
Gadolinium may be injected during part of the study to brighten the images. An EKG will be used to monitor the heart during the procedure. - Vasodilator MRI - The procedure and objectives of this test are the same as those described for dobutamine stress MRI, except that this study uses dipyridamole or adenosine. These drugs dilate blood vessels, causing increased blood flow to the heart. - Plethysmography MRI - This test determines the presence and severity of narrowing in arteries that supply blood to the leg. Blockage of these vessels often causes pain while walking. This study will compare plethysmography MRI with venous occlusion plethysmography, an older method of measuring blood flow in the legs. For venous occlusion plethysmography, a large blood pressure cuff is placed around the upper leg and a strain gauge (thin elastic band) is placed around the calf. The pressure cuff is inflated very tightly for 5 minutes to block blood flow to the leg, and another pressure cuff over the ankle is also inflated. When the large cuff is deflated, blood rushes to the leg, a smaller cuff is inflated to a low pressure, and the strain gauge measures the maximum blood flow to the leg for 1 or 2 more minutes. This procedure is done once or twice outside the MRI scanner and once or twice inside the scanner. The scans are performed as described above for the dobutamine and vasodilator studies. The strain gauge is not used for plethysmography MRI-the MRI pictures are used to measure flow.
Study Type: Interventional
Study Design: Treatment
Detailed Clinical Trial Description
The purpose of this protocol is to allow development and testing of new methods for cardiovascular MRI specifically in patients with cardiovascular disease. This protocol is comparable to protocol 97-H-0026 at the NIH and protocol 99-H-0048 except that it focuses on patients with known cardiovascular disease while the aforementioned protocols focus on normal volunteers. This protocol will provide the framework for technical development scans in patients with cardiovascular disease.
Intervention(s) in this Clinical Trial
- Procedure: Cardiovascular MRI
- N/A
Criteria for Participation in this Clinical Trial
INCLUSION CRITERIA:
Inclusion Criteria for All Arms of the Protocol:
- Patients with known or suspected cardiovascular disease will be eligible for participation in this protocol. The patient is eligible under the following conditions:
- Patient's age is greater than 21 years of age;
- Written informed consent.
Additional Inclusion Criteria for Dobutamine, Bicycle, or Vasodilator Stress MRI:
- Known or suspected coronary artery disease or valvular heart disease.
Additional Inclusion Criteria for Plethysmography:
- Known or suspected peripheral vascular disease.
EXCLUSION CRITERIA:
Exclusion Criteria for All Arms of the Protocol:
- Patients with a contraindication to MRI scanning will be excluded. These contraindications include patients with the following devices:
- Central nervous system aneurysm clips;
- Implanted neural stimulator;
- Implanted cardiac pacemaker or defibrillator;
- Cochlear implant;
- Ocular foreign body (e.g. metal shavings);
- Insulin pump;
- Metal shrapnel or bullet.
In addition, the following patient groups will be excluded:
- Pregnant women;
- Patients with surgery of uncertain type where the presence of metal clips or wires cannot be excluded;
- Patients with symptoms of myocardial ischemia occurring despite maximally tolerated doses of oral antianginal therapy and intravenous nitroglycerin.
- Furthermore, the following patient groups will be excluded from studies involving the administration of MRI contrast agents:
- lactating women;
- patients with hemoglobinopathies;
- renal disease (estimated glomerular filtration rate [eGFR] less than 30 ml/min/1.73 m(2) body surface area).
- The eGFR will be used to estimate renal function if reported by the laboratory. Otherwise, Estimated glomerular filtration rate (eGFR) can be based on the Modification of Diet in Renal Disease (MDRD) study equation (see below) in subjects with stable renal function.
This formula is not applicable to patients with acute renal insufficiency:
- eGFR (ml/min/1.73 m(2)) equal to 175 times (serum creatinine)-1.154 times (age)-0.203 times 0.742 (if the subject is female) times1.212 (if the subject is black).
Additional Exclusion Criteria for Dobutamine, Bicycle, or Vasodilator Stress MRI:
- Myocardial infarction within 48 hours (CKMB greater than 3 times normal limits);
- Uncontrolled congestive heart failure;
- Severe hypertension (SBP greater than 200, DBP greater than 100).
- Ventricular tachycardia;
- Atrial fibrillation. This exclusion only applies to Dobutamine stress.
- Frequent PVC's (more than 1 every 10 heart beats or nonsustained ventricular tachycardia (greater than 4). This exclusion only applies to Dobutamine and Bicycle stress;
- Patients with narrow angle glaucoma and known or suspected prostatic obstruction will not receive atropine.
Additional Exclusion Criteria for Plethysmography:
- Patients with patent bypass grafts at or distal to the level of occlusion.
Gender Eligibility for this Clinical Trial: Both
Minimum Age for this Clinical Trial: 21 Years
Maximum Age for this Clinical Trial: N/A
Are Healthy Volunteers Accepted for this Clinical Trial?: No
Clinical Trial Sponsor Information
Lead Sponsor: National Heart, Lung, and Blood Institute (NHLBI)
Related Publications
References
Baer FM, Voth E, Schneider CA, Theissen P, Schicha H, Sechtem U. Comparison of low-dose dobutamine-gradient-echo magnetic resonance imaging and positron emission tomography with [18F]fluorodeoxyglucose in patients with chronic coronary artery disease. A functional and morphological approach to the detection of residual myocardial viability. Circulation. 1995 Feb 15;91(4):1006-15.
Baer FM, Voth E, Theissen P, Schneider CA, Schicha H, Sechtem U. Coronary artery disease: findings with GRE MR imaging and Tc-99m-methoxyisobutyl-isonitrile SPECT during simultaneous dobutamine stress. Radiology. 1994 Oct;193(1):203-9.
Baer FM, Voth E, Theissen P, Schicha H, Sechtem U. Gradient-echo magnetic resonance imaging during incremental dobutamine infusion for the localization of coronary artery stenoses. Eur Heart J. 1994 Feb;15(2):218-25.
Additional Information
Information obtained from ClinicalTrials.gov on September 05, 2008
Link to the current ClinicalTrials.gov record. http://clinicaltrials.gov/show/NCT00027170
Study ID Number: 020050
ClinicalTrials.gov Identifier: NCT00027170
Health Authority: United States: Federal Government
Clinical Trials Authorship and Review
Clinical Trials content is provided directly by the U.S. National Institutes of Health via ClinicalTrials.gov and is not reviewed separately by ClinicalTrialsFeeds.org. Every page of specific clinical trials information contains a unique identifier which can be used to find further details directly from the National Institutes of Health.